Battery RFQ Checklist for a Victron Home Storage Project

AI-generated illustrative scene of an installer and a homeowner reviewing project plans indoors; no brand, specific model or compatibility endorsement is represented.
Illustrative discussion of home storage project requirements (AI-generated); not a specific product or installation design.

Before sending a battery request for quotation (RFQ) for a Victron home storage project, prepare the exact equipment list, the storage and power requirements, the installation details and the documents needed to confirm the proposed battery configuration. Asking only for a price per battery leaves important differences between offers unresolved.

This checklist is for installers, system integrators and distributors preparing a low-voltage residential project. It helps turn an initial enquiry into a configuration that can be reviewed and quoted. Commercial, utility-scale and high-voltage projects require a separate assessment.

1. State what the home storage system must do

Describe the intended use: solar self-consumption, backup for selected loads, off-grid operation or another defined requirement. Identify the project country and whether the battery is being added to an existing system or included in a new installation.

List the circuits or loads the project is intended to serve. Separate the required energy capacity from the required output power, and identify any starting loads or backup-duration expectations. Include the load profile and design assumptions available to the installer. If these have not been established, request a technical review rather than presenting an estimate as an agreed specification.

This gives suppliers a shared basis for discussing battery quantity and system design without selecting a battery solely from its advertised capacity.

2. Identify the actual Victron equipment

Provide the full inverter/charger model designation, system voltage, device quantity and arrangement. Include the GX device, solar chargers and other relevant equipment. For an existing installation, attach its equipment schedule and the firmware versions recorded from the devices.

Explain which components will remain and which may be replaced. Identify any existing batteries separately, including their model and age, and ask whether the proposed configuration involves replacement or expansion. Do not assume that different battery versions can be combined.

Victron's battery-compatibility directory provides links to battery-specific guidance. Use the applicable page alongside the actual equipment schedule; a brand-level compatibility statement is not a complete system specification.

3. Ask for evidence for the proposed battery version

Request the exact battery designation, datasheet revision, BMS identification, applicable firmware and installation manual. Ask the supplier to explain how those documents correspond to the units it proposes to supply.

For a Voltsmile offer, consult Victron's Voltsmile integration guidance. It covers named battery models and specifies conditions involving Victron equipment, BMS firmware, communication hardware and configuration. Have the supplier and installer match the offer against those conditions, rather than transferring one model's information to another product with a similar name.

Keep three questions distinct: is the model covered by the relevant guidance, does the proposed version meet its conditions, and is the complete configuration suitable for the project? Record the evidence and the party responsible for each answer.

4. Include communications and control in the quotation

Ask the supplier to identify the required communication cable, GX connection, configuration responsibilities and commissioning documents. List separately any cables, protection equipment, mounting components or other accessories that are included or excluded.

Victron's DVCC requirements direct installers to check battery-specific support and firmware requirements. Settings should follow the applicable integration instructions. Do not use a generic checklist as a substitute for those instructions or copy settings from an unrelated battery.

Ask who will verify communication, reported battery information and the agreed operating behaviour during commissioning. If a system contains additional chargers or loads, have the installer include them in the design review.

5. Describe the installation and supply boundaries

Provide the intended indoor or outdoor location, available space, mounting arrangement and expected environmental conditions. Attach photographs or drawings where useful. Ask the installer to review placement, access, wiring routes and the applicable installation requirements against the proposed product documents.

Distinguish the battery supply from installation and system commissioning. Request written confirmation of the documentation, accessories, transport arrangements and support contacts included in the quotation. Ask for the applicable warranty document rather than relying on a general statement about warranty length.

If future expansion is planned, state it now. Request a documented explanation of the conditions that would apply; do not treat an initial expansion intention as confirmation that any later battery can be added.

6. Return a response that can be compared

Use the same response format for every supplier:

RFQ item: System purpose

Information to provide
Operating goal, load information and location

Response to request
Assumptions and outstanding design questions

RFQ item: Equipment

Information to provide
Exact Victron models, arrangement and firmware

Response to request
Configuration-specific compatibility evidence

RFQ item: Battery

Information to provide
Capacity and power requirements

Response to request
Exact model, version, quantity and documents

RFQ item: Integration

Information to provide
Existing devices and communication requirements

Response to request
Cable, settings and commissioning scope

RFQ item: Installation

Information to provide
Site details and mounting constraints

Response to request
Accessories, exclusions and installation conditions

RFQ item: Handover

Information to provide
Required records and responsible parties

Response to request
Commissioning evidence and applicable support terms

Require suppliers to separate confirmed items, proposed options and questions that remain open. Keep the quotation revision with its equipment and document references so that later substitutions can be reviewed against the same requirements.

AI-generated illustrative scene of an installer reviewing a folder and tablet for a home storage enquiry; not a real delivery case.
Illustrative review of equipment information and handover documents (AI-generated).

Prepare the enquiry package

Send the project brief, equipment schedule, load information, site details and required response table together. Include the delivery destination, requested schedule and the contact responsible for technical clarification. Ask for a revised written offer if the proposed model or scope changes.

Use Voltsmile's low-voltage selection information to review the existing product and document routes, then discuss the project requirements. A useful battery quote identifies the configuration being offered, the evidence supporting it and the work required to commission it.

+86 755 86031669